Immunoglobulin G (IgG) Heavy and Light Chain (HLC) Pairs, κ and λ With Ratio

CPT 83521(x2)
Synonyms
  • Hevylite IgG
  • HLC IgG
  • IgG κ:λ HLC Ratio

Test Details

Methodology

Turbidimetric

Result Turnaround Time

4 - 6 days

Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.

Related Documents

For more information, please view the literature below.

Published Plasma Cell Dyscrasias Selection Table

Use

For the quantitative measurement of human IgG heavy chain and light chain intact immunoglobulin in serum. The IgG HLC ratio can be used when monitoring previously diagnosed IgG multiple myeloma in conjunction with other laboratory tests and clinical evaluations.

Heavy and light chain pair quantitation may be useful for:

1. Distinguishing between broadly migrating monoclonal proteins and restricted polyclonal immunoglobulin patterns on serum protein electrophoresis.

2. Quantitating monoclonal IgG proteins that are difficult to quantitate using serum protein electrophoresis alone.

3. Providing a more specific quantitation of the monoclonal protein than total IgG measurements alone.

Limitations

Decisions on patient evaluation and management must not be given on the basis of IgG κ, IgG λ, or IgG κ:IgG λ ratio measurements alone. Clinical history and other laboratory findings must be taken into account.

Heavy and light chain (HLC) quantitation should be used as a complementary method to serum protein electrophoresis.

The effect of therapeutic drugs on the measurement of IgG κ and IgG λ by this assay has not been evaluated.

Small increases in the concentrations of monoclonal IgG proteins may not result in an altered HLC pair ratio.

For initial detection of monoclonal proteins, see:

Immunofixation (IFE), Serum and Protein Electrophoresis, Serum [001495]

Immunofixation (IFE), Serum, Protein Electrophoresis (PE), Serum, and Quantitative Free κ and λ Light Chains (FLC) Plus Ratio, Serum [120256]

Immunofixation (IFE) and Protein Electrophoresis, 24-Hour Urine [003467]

Custom Additional Information

Elevated serum concentrations of monoclonal protein are indicative of an underlying abnormality, such as monoclonal gammopathy of undetermined significance (MGUS), multiple myeloma, and other lymphoproliferative disorders. International guidelines recommend serum protein electrophoresis or nephelometric immunoglobulin quantification as tools to monitor patients' disease1 (alongside other tests including flow cytometry and serum free light chain analysis).2 Total IgG nephelometric assays will include nontumor immunoglobulin, and measurement of either IgG κ or IgG λ may give a more accurate representation of tumor production.

Furthermore, measurement of both IgG κ and IgG λ, calculation of the IgG κ:IgG λ ratio, and comparison with values found in normal subjects can give a more sensitive indication of clonality.3-5 Additionally, changes in the IgG κ:IgG λ ratio and its normalization when compared to a normal ratio range should assist in monitoring patients' disease. Use of the IgG κ:IgG λ ratio will also compensate for any changes in plasma volume and correct for half life variations due to receptor saturation.

Specimen Requirements

Specimen

Serum

Volume

0.75 mL

Minimum Volume

0.5 mL

Container

Red-top tube or gel-barrier tube

Collection Instructions

Separate serum immediately after coagulation (30 minutes) to prevent hemolysis.

Stability Requirements

Temperature

Period

Room temperature

14 days

Refrigerated

14 days

Frozen

14 days

Freeze/thaw cycles

Stable x3

Reference Range

• IgG κ (g/L): 4.03−9.78

• IgG λ (g/L): 1.97−5.71

• IgG κ:IgG λ ratio: 0.98−2.75

An elevated IgG heavy and light chain (HLC) pair ratio suggests a clonal proliferation of an IgG κ clone of plasma cells.

A low IgG HLC pair ratio suggests a clonal proliferation of an IgG λ clone of plasma cells.

Storage Instructions

Refrigerate.

Causes for Rejection

Microbially-contaminated specimen; specimen containing particulate matter; lipemic or hemolyzed specimen

Footnotes

1. Dimopoulos M, Kyle R, Fermand JP, et al. Consensus recommendations for standard investigative workup: Report of the International Myeloma Workshop Consensus Panel 3. Blood. 2011 May 5; 117(18):4701-4705. 21292778
2. Rajkumar SV, Harousseau JL, Durie B, et al. Concensus recommendations for the uniform reporting of clinical trials: Report of the International Myeloma Workshop Consensus Panel 1. Blood. 2011 May 5; 117(18):4691-4695. 21292775
3. Bradwell AR, Harding SJ, Fourrier NJ, et al. Assessment of monoclonal gammopathies by nephelometric measurement of individual immunoglobulin kappa/lambda ratios. Clin. Chem. 2009 Sep; 55(9):1646-1655. 19617289
4. Ludwig H, Milosavljevic D, Zojer N, et al. Immunoglobulin heavy/light chain ratios improve paraprotein detection and monitoring, identify residual disease and correlate with survival in multiple myeloma patients. Leukemia. 2013 Jan; 27(1):213-219. 22955329
5. Bradwell A, Harding S, Fourrier N, et al. Prognostic utility of intact immunoglobulin Ig'κ/Ig'λ ratios in multiple myeloma patients. Leukemia. 2013 Jan; 27(1):202-207. 22699454

LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
123550 IgG Heavy Light Chains(HLC), S 123534 IgG Kappa, S g/L 74862-4
123550 IgG Heavy Light Chains(HLC), S 123535 IgG Lambda, S g/L 74863-2
123550 IgG Heavy Light Chains(HLC), S 123536 IgG K/L HLC Ratio Ratio 74868-1
Order Code123550
Order Code NameIgG Heavy Light Chains(HLC), S
Order Loinc
Result Code123534
Result Code NameIgG Kappa, S
UofMg/L
Result LOINC74862-4
Order Code123550
Order Code NameIgG Heavy Light Chains(HLC), S
Order Loinc
Result Code123535
Result Code NameIgG Lambda, S
UofMg/L
Result LOINC74863-2
Order Code123550
Order Code NameIgG Heavy Light Chains(HLC), S
Order Loinc
Result Code123536
Result Code NameIgG K/L HLC Ratio
UofMRatio
Result LOINC74868-1