For hours, walk-ins and appointments.7 - 14 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
Serum
5 mL
2.3 mL (Note: This volume does not allow for repeat testing.)
Gel-barrier tube or red-top tube
Allow a minimum clotting time of 30 to 60 minutes with serum separation within 2 hours of collection.
Refrigerate
Temperature | Period |
---|---|
Room temperature | 1 day |
Refrigerated | 7 days |
Frozen | 60 days |
Freeze/thaw cycles | Stable x6 |
Gross hemolysis; lipemia; icteric specimen
ReproSURE™ is a blood test comprised of Anti-Müllerian Hormone (AMH), Follicle Stimulating Hormone (FSH), and Estradiol designed to provide information about ovarian reserve. Ovarian reserve is a term used to describe a woman's reproductive potential, including the number of oocyttes (eggs) she possesses.
1. ReproSURE is a blood test comprised of AMH, FSH and Estradiol hormones designed to provide information about ovarian reserve.
2. While no laboratory test can predict pregnancy, these ovarian reserve tests assess oocyte quantity and help predict ovarian response to stimulation in order to individualize fertility options including assisted reproductive technology (ART) treatment.
3. Correct timing of blood collection is important. Serum specimen for ReproSURE testing should be collected on day 3 of your menstrual cycle. Day 2 or 4 collection may also be acceptable. FSH and estradiol levels rise and fluctuate after cycle day 3. If FSH and estradiol levels are higher than expected, you may wish to verify the cycle day of the blood collection.
4. These tests are not the sole criteria used to determine appropriateness of ART or any other treatment.
5. These tests do not evaluate egg quality. Egg quality peaks in a woman's twenties and then declines with age.
6. Antral follicle count (AFC) is another measure of egg supply that can be obtained by ultrasound observation.
Blood sample should be collected on day 3 of menstrual cycle as target ranges for ovarian assessment are based on day 3 concentrations.
Anti-Müllerian Hormone: Electrochemiluminescence; FSH: Electrochemiluminescence; Estradiol: LC-MS/MS
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
504295 | ReproSURE | 504585 | Overview | 77202-0 | ||
504295 | ReproSURE | 500184 | Anti-Mullerian Hormone (AMH) | ng/mL | 38476-8 | |
504295 | ReproSURE | 500098 | Follicle Stimulating Hormone | mIU/mL | 15067-2 | |
504295 | ReproSURE | 502608 | Estradiol, Serum, MS | pg/mL | 35384-7 | |
504295 | ReproSURE | 504586 | Comments | 75608-0 |
Reflex Table for Comments | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 910395 | ReproSure Patient Education | 910396 | Note | N/A |
Reflex Table for Comments | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 910395 | ReproSure Patient Education | 910397 | N/A |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf