Anti-PM/Scl-100 Ab (RDL)

CPT: 86235
Print Share

Synonyms

  • PM Scler
  • PM/SCL
  • PM/SCL100

Test Includes

This test is a component of Interstitial Lung Disease Panel I, Interstitial Lung Disease Panel II, Myomarker 3 Profile, Myomarker 3 Plus Profile, Scleroderma Comprehensive Profile.


Expected Turnaround Time

5 - 7 days


Related Documents


Specimen Requirements


Specimen

Serum


Volume

1 mL


Minimum Volume

0.3 mL (Note: This volume does not allow for repeat testing.)


Container

Red-top tube or gel-barrier tube


Collection

Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.


Storage Instructions

Refrigerate or freeze.


Stability Requirements

Temperature

Period

Room temperature

7 days

Refrigerated

14 days

Frozen

60 days

Freeze/thaw cycles

Stable x1


Causes for Rejection

Grossly hemolyzed; bacterial contamination; lipemic specimen; icteric specimen; non-serum specimen types


Test Details


Use

The anti-PM/Scl-100 antibody is associated with younger age, calcinosis and has lower rates of gastrointestinal symptoms, ILD and pulmonary hypertension. There is also evidence of a possibly better survival compared to the presence of either anti-PM/Scl-75 or anti-Scl-70 antibodies.


Limitations

This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.


Methodology

Enzyme-linked immunosorbent assay (ELISA)


LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
520007 Anti-PM/Scl-100 Ab (RDL) 101221-0 520048 Anti-PM/Scl-100 Ab (RDL) Units 101221-0

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf