11-Deoxycortisol, Two Specimens

CPT: 82634(x2)
Print Share

Synonyms

  • 11-Desoxycortisol

Special Instructions

Submit two tubes; one vial labeled as baseline and one labeled as post-metyrapone.


Expected Turnaround Time

6 - 8 days


Specimen Requirements


Specimen

Serum (preferred) or plasma, frozen


Volume

0.5 mL (each specimen)


Minimum Volume

0.2 mL (each specimen) (Note: This volume does not allow for repeat testing.)


Container

Red-top tube, gel-barrier tube, lavender-top (EDTA) tube, or green-top (heparin) tube


Collection

Transfer serum into a frozen lavender transport tube with cap (LabCorp ID 9566589372). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.


Storage Instructions

Freeze.


Stability Requirements

Temperature

Period

Room temperature

1 day

Refrigerated

1 day

Frozen

2 years

Freeze/thaw cycles

Stable x3


Test Details


Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS) after chromatography and solvent extraction


LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
500560 11-Desoxycortisol, 2 Specs 500561 11-Desoxycortisol #1 ug/dL 40810-4
500560 11-Desoxycortisol, 2 Specs 500562 11-Desoxycortisol #2 ug/dL 41289-0

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf