Phenytoin, Free and Total, Serum

CPT: 80185; 80186
Print Share

Synonyms

  • Dilantin-125®
  • Dilantin®
  • Free and Total Phenytoin
  • Phenytek®

Expected Turnaround Time

2 - 5 days


Related Documents


Specimen Requirements


Specimen

Serum or plasma


Volume

3 mL


Minimum Volume

2.3 mL


Container

Red-top tube or green-top (heparin) tube. Do not use a gel-barrier tube. The use of gel-barrier tubes is not recommended due to slow absorption of the drug by the gel. Depending on the specimen volume and storage time, the decrease in drug level due to absorption may be clinically significant.


Collection

Transfer separated serum or plasma to a plastic transport tube. Collect specimen just prior to next dose. Serum or plasma must be separated from cells within 45 minutes of collection. Send serum or plasma in a plastic transport tube.


Storage Instructions

Room temperature


Stability Requirements

Temperature

Period

Room temperature

14 days

Refrigerated

14 days

Frozen

14 days

Freeze/thaw cycles

Stable x3


Causes for Rejection

Gel-barrier tube; hemolysis; lipemia


Test Details


Use

Evaluate toxicity; monitor therapeutic levels


Methodology

Total: immunoassay; Free: ultrafiltrate assayed by immunoassay


LOINC® Map

Order Code Order Code Name Order Loinc Result Code Result Code Name UofM Result LOINC
070706 Phenytoin,Free and Total,Serum 34540-5 070778 Phenytoin, Serum ug/mL 3968-5
070706 Phenytoin,Free and Total,Serum 34540-5 070763 Phenytoin, Free, Serum ug/mL 3969-3

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf