Find Locations
For hours, walk-ins and appointments.Unable to load global navigation.
Find Locations
For hours, walk-ins and appointments.7 - 10 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
Whole blood or Labcorp buccal swab kit (buccal swab collection kit contains 4 swabs and instructions for use of a buccal swab)
2 mL whole blood or one buccal swab kit (4 swabs)
1 mL whole blood or two buccal swabs
Lavender-top (EDTA) tube or yellow-top (ACD) tube or Labcorp buccal swab kit
Collect specimen in a lavender-top (EDTA) or yellow-top (ACD) tube, or use a buccal swab kit (4 swabs). Ship whole blood specimen at room temperature or frozen. Ship buccal swab kit at room temperature.
Maintain whole blood specimen at room temperature or refrigerated for 28 days or frozen for 2 years. Maintain buccal swabs at room temperature for 2 months.
Temperature | Period |
---|---|
Room temperature | Whole Blood: 28 days Swabs: 2 Months |
Refrigerated | Whole Blood: 28 days Swabs: Unstable |
Frozen | Whole Blood: 2 years Swabs: Unstable |
Quantity not sufficient for analysis; improper container; single buccal swab; wet buccal swab; buccal swabs without outer collection envelope; severely damaged buccal swab envelope; buccal swab envelope received open; frozen glass tube
Cytochrome P450 2C19 (CYP2C19) is a drug-metabolizing enzyme involved in the metabolism of several clinically important drugs including the platelet aggregation inhibitor clopidogrel, the tricyclic antidepressants amitriptyline and nortriptyline, the selective serotonin reuptake inhibitors citalopram and sertraline, and some proton pump inhibitors including omeprazole and pantoprazole. Individuals with some variant CYP2C19 alleles may experience a reduced therapeutic response and may be at risk for side effects from drugs that are metabolized by CPY2C19. CYP2C19 genotype information can be utilized to predict CYP2C19 metabolic phenotype, which can be used as an aid in determining a therapeutic strategy for drugs that are metabolized by CYP2C19. For example, the use of clopidogrel with an intermediate or poor metabolizer is associated with reduced platelet inhibition and an increased risk of cardiovascular complications, such as myocardial infarction, stroke, stent thrombosis and/or death, as compared with normal metabolizers. In these instances, alternative drugs may be considered. Ultrarapid metabolism is associated with lower platelet activity, but there is no association with higher bleeding risk.
Variation in the CYP2C19 gene can result in ultrarapid (UM), rapid (RM), normal (NM), intermediate (IM), likely intermediate (LIM), poor (PM) and likely poor (LPM) drug-metabolizing phenotypes. In general, relative to the *1 allele (normal function), the *17 allele has increased function, *9 and *10 alleles have decreased function, while *2, *3, *4, *5, *6, *7, *8 and *35 alleles have no function.
The exact effect of a particular genotype on individual drugs can vary. In addition to genotype, the metabolism of drugs may be influenced by additional factors that include environmental, dietary and other medications; these factors and others should be considered prior to initialing a new therapy. All results must be interpreted in the context of other test results and clinical findings. Results do not rule out the possibility of other variant alleles in CYP2C19 or other variant alleles in other drug metabolism pathways. Patients should speak with their healthcare provider about the individual results of this test.
Molecular-based testing is highly accurate, but as in any laboratory test, rare diagnostic errors may occur.
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
DNA analysis is performed by allele-specific real-time polymerase chain reactions (RT-PCR) to detect single-nucleotide polymorphisms (SNPs) within the CYP2C19 gene and to assign variant CYP2C19 *2, *3, *4, *5, *6, *7, *8, *9, *10, *17 and *35 alleles. *1 denotes detection of the reference (wild-type) sequence at the assessed alleles. No other variants in this gene are detected by this assay.
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf