Herpes Simplex Virus Type 1 (HSV-1), Type Specific Antibodies, IgG

CPT: 86695
Updated on 10/14/2024
Print Share

Synonyms

Herpes-1; HSV Type-1 Specific Antibody, IgG; HSV-1; HSV


Test Includes

This test includes detection of antibodies specific to herpes type 1 only.


Expected Turnaround Time

1 - 2 days


Related Documents


Specimen Requirements


Specimen

Serum


Volume

1.0 mL


Minimum Volume

0.4 mL (Note: This volume does not allow for repeat testing.)


Container

Red-top tube, gel-barrier tube or serum transfer tube


Collection

If tube other than a gel-barrier is used, transfer separated serum to a plastic transport tube.


Storage Instructions

Refrigerate.


Stability Requirements

TemperaturePeriod
Room temperature2 days
Refrigerated7 days
Frozen12 weeks
Freeze/Thaw CycleStable x5

Causes for Rejection

Gross hemolysis; obvious microbial contamination and/or received outside of specimen and/or storage and/or requirements; heat-inactivated samples


Test Details


Use

This test is used for qualitative detection of IgG antibodies specific to HSV type 1. This test is intended for sexually active individuals and pregnant individuals as an aid in the presumptive diagnosis of HSV-1 infection. The test results may not determine the state of active lesions or associated disease manifestations, particularly in primary infection. The predictive value of positive an negative results depends on the population's prevalence and the pretest likelihood of HSV-1. The detection of HSV-1 IgG antibodies in a single sample indicates a previous exposure to HSV-1 but does not give information as to the site of HSV infection or the timing of exposure.

There is a considerable homology between HSV-1 and HSV-2 antigens, so that antibodies formed against either virus are highly crossreactive. This assay is based on purified recombinant glycoprotein G-1 and is specific for type 1 antibodies. Moreover, this assay is highly sensitive and specific and will not detect antibodies to HSV-2.


Limitations

A negative test result does not completely rule out the possibility of an infection with HSV 1. Individuals may not exhibit any detectable IgG antibodies at the early stage of acute infection. False negative results may occur when the HSV virus is glycoprotein G (gG) deficient (0.2% HSV isolates were gG deficient). The results in HIV patients, in patients undergoing immunosuppressive therapy or in patients with other disorders leading to immune suppression, should be interpreted with caution. Specimens from neonates, cord blood, pretransplant patients or body fluids other than serum and plasma, such as urine, saliva or amniotic fluid, have not been tested. The results should always be assessed in conjunction with the patient's medical history, clinical examination and other findings.

A negative test result does not completely rule out the possibility of an infection with HSV 1. Individuals may not exhibit any detectable IgG antibodies at the early stage of acute infection. False negative results may occur when the HSV virus is glycoprotein  G (gG) deficient (0.2% HSV isolates were gG deficient). The results in HIV patients, in patients undergoing immunosuppressive therapy or in patients with other disorders leading to immune suppression, should be interpreted with caution. Specimens from neonates, cord blood, pretransplant patients or body fluids other than serum and plasma, such as urine, saliva or amniotic fluid, have not been tested. The results should always be assessed in conjunction with the patient's medical history, clinical examination and other findings.

A negative test result does not completely rule out the possibility of an infection with HSV 1. Individuals may not exhibit any detectable IgG antibodies at the early stage of acute infection. False negative results may occur when the HSV virus is glycoprotein G (gG) deficient (0.2% HSV isolates were gG deficient). The results in HIV patients, in patients undergoing immunosuppressive therapy or in patients with other disorders leading to immune suppression, should be interpreted with caution. Specimens from neonates, cord blood, pretransplant patients or body fluids other than serum and plasma, such as urine, saliva or amniotic fluid, have not been tested. The results should always be assessed in conjunction with the patient's medical history, clinical examination and other findings.


Methodology

Electrochemiluminescience immunoassay (ECLIA)


References

Miller JM, Binnicker MJ, Campbell S, et al. Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM). Clin Infect Dis. 2024 Mar 5:ciae104. PubMed 38442248

Workowski, Bachmann, Chan et al. Sexually Transmitted Infections Treatment Guidelines, 2021. MMWR Recomm Rep. 2021;70(4):1-187. PubMed 34292926

Miller JM, Binnicker MJ, Campbell S, et al. Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Deseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM). Clin Infect Dis. 2024 Mar 5:ciae104. PubMed 38442248

Workowski, Bachmann, Chan et al. Sexually Transmitted Infections Treatment Guidelines, 2021. MMWR Recomm Rep. 2021;70(4):1-187. PubMed 34292926

Miller JM, Binnicker MJ, Campbell S, et al. Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2024 Update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM). Clin Infect Dis. 2024 Mar 5:ciae104. PubMed 38442248

Workowski, Bachmann, Chan et al. Sexually Transmitted Infections Treatment Guidelines, 2021. MMWR Recomm Rep. 2021;70(4):1-187. PubMed 34292926


LOINC® Map

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf